2

OUTPUT 0 to 20 VDC, continuously adjustable, at 0 to
500 MA.
INPUT 105 to 125 V, 50 to 440 Hz, 40 W max. (including
oven heater).
CALIBRATION AND ACCURACY Two dual, concentric,
decade switches provide dial readout to four places
with an accuracy of 0.1% ± 1 MV at outputs below 10 V.
A 1-MV range, single-turn potentiometer permits inter-
polation of the last place. This potentiometer has a
resolution of 10 uV. A toggle switch extends the range
of the dial readout from 10 to 20 V, without affecting
resolution or accuracy (five-place readout). An illumi-
nated indicator identifies the range in operation.
REGULATION Output voltage change less than 100 uV
(at sense connection points) for line or load variations
over the operating range.
RIPPLE AND NOISE Less than 100 uV peak-to-peak.
SOURCE IMPEDANCE Less than 0.2 milliohm at DC, 0.04
ohm at 20 KHz, 0.5 ohm at 1 MHz.
RECOVERY TIME Less than 10 uS to return to within
250 uV or 0.005% (whichever is greater) of the set
voltage for a 10% to 100% step change in rated
load; less than 40 uS to return with 100 uV.
OPERATING TEMPERATURE RANGE 15 to 4 °C ambient;
0 to 60 °C ambient with reduced accuracy.
TEMPERATURE COEFFICIENT DC output voltage change
less than 0.001% or 50 uV (whichever is greater) per
°C over the range of + 15 to +45 °C; less than 0.002%
or 100 uV (whichever is greater) per °C from 0 to + 15
°C and +45 to +60 °C.
STABILITY Better than 0.001% + 100 MV/8 hrs.; better
than 1 MV/wk (at constant ambient temperature, load
and line voltage, after warmup).
OUTPUT TERMINALS Three front-panel binding posts and
rear-panel barrier block. Either positive or negative
output terminal may be grounded.
METER Front-panel volt-ammeter permits monitoring out-
put voltage or current with an accuracy of ±2%.
REMOTE SENSING Two terminals on rear-panel barrier
block are provided for remote sensing of voltage at the
load.
REMOTE PROGRAMMING Rear terminals are provided for
remote programming of the output voltage at 1000
ohms-per-volt. Accuracy of programming is better than
0.01% of value of resistance (including connecting
leads).
CURRENT LIMITING The output current can be limited
to any value from 0 to 500 MA by a front-panel control.
A push-button permits easy adjustment without the
need for shorting the output terminals.


MECHANICAL SPECIFICATIONS

DIMENSIONS 8 3/8” x 4 3/4" x 8-15/16”
WEIGHT 9 pounds
FINISH Brushed anodized aluminum panel with etched
black lettering. Dust cover finished in blue enamel;
chassis and bottom plate, golden indite.

2